EnoughToGet CalculatorsGuides

Landscaping

Retaining wall calculator

Concrete sleeper retaining wall: how many sleepers and posts, and the drainage gravel behind it.

Try itRetaining wall: enter your own sizes
m
Type metres, for example 8.5.
m
The height of soil the wall holds back, not including the footing.
Posts stand at each sleeper joint, so post spacing equals the sleeper length. Pick the length your supplier stocks.
mm
Read it from your sleeper. 200 mm is only a typical starting value.
mm
600 mm is the RetWall figure for low walls. Taller walls need deeper footings from the engineer.
You need
16 sleepers
5 posts, 0.8 m high

Shopping list

ItemBuyNote
Concrete sleepers, 2400 mm16 sleepers4 courses of 4
Steel posts, 1.40 m long5 posts600 mm in the ground
Drainage gravel behind the wall1.92 m³about 2.78 t
  • Retaining walls higher than about 0.6 m usually need an engineer's design or approval (RetWall). Rules differ by state and council: check yours before you buy.
  • Post spacing here equals the sleeper length. RetWall quotes 1.2 m between posts for tall walls and up to 2.4 m for shorter ones, and the footing depth grows with the wall: the engineer sets spacing, steel size and footing depth. This count is for planning only.
How this was worked out
  1. Courses: height ÷ sleeper height, rounded up
    800 ÷ 200 = 4 courses
  2. Sleepers per course: length ÷ sleeper length, rounded up
    8000 ÷ 2400 = 4 sleepers
  3. Sleepers: courses × sleepers per course
    4 × 4 = 16 sleepers
  4. Posts: sleepers per course + 1
    4 + 1 = 5 posts
  5. Post length: retained height + footing depth
    0.8 + 0.6 = 1.4 m
  6. Drainage gravel: length × gravel width × height × density
    8 × 0.3 × 0.8 × 1.45 = 2.78 t

Retaining wall needed by size

Wall (m, length × height)Main resultShopping list
4 × 0.66 sleeper6 sleeper Concrete sleepers, 2400 mm; 3 post Steel posts, 1.20 m long; 0.72 m³ Drainage gravel behind the wall
6 × 0.812 sleeper12 sleeper Concrete sleepers, 2400 mm; 4 post Steel posts, 1.40 m long; 1.44 m³ Drainage gravel behind the wall
8 × 0.816 sleeper16 sleeper Concrete sleepers, 2400 mm; 5 post Steel posts, 1.40 m long; 1.92 m³ Drainage gravel behind the wall
10 × 125 sleeper25 sleeper Concrete sleepers, 2400 mm; 6 post Steel posts, 1.60 m long; 3 m³ Drainage gravel behind the wall
12 × 1.230 sleeper30 sleeper Concrete sleepers, 2400 mm; 6 post Steel posts, 1.80 m long; 4.32 m³ Drainage gravel behind the wall

Australian figures with every other setting at its default. Change them in the calculator, or switch to New Zealand.

How it is calculated

  1. Courses: height ÷ sleeper height, rounded up
    800 ÷ 200 = 4 courses
  2. Sleepers per course: length ÷ sleeper length, rounded up
    8000 ÷ 2400 = 4 sleepers
  3. Sleepers: courses × sleepers per course
    4 × 4 = 16 sleepers
  4. Posts: sleepers per course + 1
    4 + 1 = 5 posts
  5. Post length: retained height + footing depth
    0.8 + 0.6 = 1.4 m
  6. Drainage gravel: length × gravel width × height × density
    8 × 0.3 × 0.8 × 1.45 = 2.78 t

What to enter

FieldUnitHelp
Wall lengthmType metres, for example 8.5.
Retained heightmThe height of soil the wall holds back, not including the footing.
Sleeper lengthchoosePosts stand at each sleeper joint, so post spacing equals the sleeper length. Pick the length your supplier stocks.
Sleeper face heightmmRead it from your sleeper. 200 mm is only a typical starting value.
Footing depthmm600 mm is the RetWall figure for low walls. Taller walls need deeper footings from the engineer.

Before you buy

Frequently asked questions

How do I calculate retaining wall?

Concrete sleeper retaining wall: how many sleepers and posts, and the drainage gravel behind it. Enter your sizes in the calculator. It works out courses (height ÷ sleeper height, rounded up) and the later steps, then rounds up to whole packs.

Where does the retaining sleeper length 1800 figure come from?

1,800 mm. Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths. Checked against its source on 2026-11-18.

Where does the retaining sleeper length 2000 figure come from?

2,000 mm. Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths. Checked against its source on 2026-11-18.

Where does the retaining sleeper length 2400 figure come from?

2,400 mm. Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths. Checked against its source on 2026-11-18.

Where does the retaining sleeper height figure come from?

200 mm. Typical sleeper face height. No Australian supplier figure was read for this: check the height of the sleeper you will buy and change it. This is an editable starting value, not an official figure. Change it if your product label or supplier says otherwise.

Does this calculator work for New Zealand?

Yes. Switch the region to New Zealand. Where New Zealand products or coverage differ, such as Resene paint coverage and GIB plasterboard sheets, the calculator uses the New Zealand figure.

Does it show prices?

No. It gives quantities and a shopping list. Ask your supplier for prices.

Sources and assumptions

These are the settings behind every number above. Verified figures link to a source. Editable defaults are common rules of thumb: change them to match your product and your site.

SettingValueStatusSource
retaining sleeper length 18001,800 mmVerified 2026-11-18Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths.
retaining sleeper length 20002,000 mmVerified 2026-11-18Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths.
retaining sleeper length 24002,400 mmVerified 2026-11-18Outwest Sleepers (Victorian supplier): concrete sleepers are supplied in 1800, 2000 and 2400 mm lengths.
retaining sleeper height200 mmEditable defaultTypical sleeper face height. No Australian supplier figure was read for this: check the height of the sleeper you will buy and change it.
retaining post spacing min1.2 mVerified 2026-11-18RetWall: post spacing is typically 1.2 m for tall walls up to 2.4 m for shorter walls (concrete sleeper walls). The engineer sets the real spacing.
retaining post spacing max2.4 mVerified 2026-11-18RetWall: post spacing is typically 1.2 m for tall walls up to 2.4 m for shorter walls (concrete sleeper walls). The engineer sets the real spacing.
retaining footing depth low600 mmVerified 2026-11-18RetWall: footing depth typically 600 mm for low walls, up to 1500 mm or more for walls approaching 2.4 m.
retaining engineer height0.6 mEditable defaultRetWall (a retaining wall company, not an authority): engineering or a permit is typically required above 0.60 m of retained height, or for any wall on a boundary…
retaining drain gravel width300 mmEditable defaultAbout 300 mm of clean drainage gravel behind the wall (Yakka Labour and tryBuildCalc guides, not manufacturers). RetWall also specifies a 100 mm ag drain wrapped in…
landscape density bluemetal1.45 t/m3Verified 2026-11-18Australian Native Landscapes product weights FAQ: blue metal 1.45 t/m3.

Related calculators