Paint & plaster
How many plasterboard sheets do I need for a room?
To line a 4 x 3.5 m room with a 2.4 m high ceiling, you will need 20 sheets of 10 mm plasterboard (1200 x 2400 mm) to cover both the walls and the 14 m2 ceiling.
Shopping list
| Item | Buy | Note |
|---|---|---|
| Plasterboard 10 mm, 1200 × 2400 mm | 14 sheets | 2.88 m² each |
| Plasterboard screws | 317 screws | 8 per m², a rule of thumb: check the maker's guide |
| Jointing compound, 20 kg packs | 1 pack | 9.4 kg for topping and base coat |
| Cornice (length of wall to cover) | 15 m | Cornice lengths vary by product: divide by the length you buy |
- For ceilings, Gyprock's guidance is framing at no more than 450 mm centres with fasteners at no more than 300 mm. Check your product's installation guide for walls.
How this was worked out
- Area to line:
wall length × height + ceiling − openings
15 × 2.4 + 0 − 0 = 36 m² - One sheet:
width × length
1.2 × 2.4 = 2.88 m² - Sheets:
area × (1 + waste) ÷ sheet area, rounded up
36.00 × 1.10 ÷ 2.880 = 13.75 sheets - Screws:
area × (1 + waste) × screws per m²
39.6 × 8 = 317 screws - Jointing compound:
area × (topping + base coat per m²)
36.0 × (0.1 + 0.16) = 9.36 kg
Calculating Wall and Ceiling Area
Plasterboard Sheet Requirements
The number of sheets required depends on the dimensions of the boards you choose. Standard sizes for plasterboard include widths of 900 mm, 1200 mm, 1350 mm, and 1400 mm. Common lengths include 2400 mm, 2700 mm, 3000 mm, 3600 mm, 4200 mm, 4800 mm, and 6000 mm. For a 50 m2 area using 1200 x 2400 mm sheets, the calculator determines you need 19.1 sheets. Because you cannot purchase partial sheets, you must round up to 20 sheets. This calculation includes a 10% waste factor, which is a common trade rule of thumb for cuts and offcuts. If you choose a different sheet size, such as 1200 x 2700 mm, the number of sheets will change based on the increased surface area per board.
Fasteners and Spacing
Securing the plasterboard to the framing requires a specific quantity of screws. The GIB site guide (April 2024) and the GIB site guide (2024) for New Zealand both suggest a coverage of approximately 800 screws per 100 m2 of plasterboard. This equates to a rule of thumb of 8 screws per m2. For a 50 m2 project, this results in a requirement of 441 screws. When installing, the Gyprock FAQ states that fasteners should be placed at a maximum of 300 mm centres. Similarly, the GIB general wall and ceiling installation guide for New Zealand specifies a maximum of 300 mm centres around the sheet perimeter. Always ensure your framing is prepared correctly to receive these fasteners at the required intervals.
Jointing Compound and Topping
Once the sheets are fixed, you will need jointing compound to finish the seams and screw heads. The amount of compound depends on whether you are applying a base coat or a topping. Gyprock Jointmaster topping coverage is 10 kg per 100 m2, while Gyprock Base Coat 20/45/60/90 coverage is approximately 16 kg per 100 m2. For a 50 m2 area, the topping requirement is 13 kg. Since these products are sold in 20 kg packs, you will need to purchase 1 pack. For the base coat, the calculation for a 50 m2 area results in 13 kg of compound. Check your product label or supplier for specific coverage rates as they can vary between different types of compound.
Cornice and Trim
Cornice is used to finish the joint between the wall and the ceiling. In Australia, the length of cornice required is typically based on the total length of the wall to cover. For a 15 m wall, you would need 15 m of cornice. In New Zealand, the GIB site guide (April 2024) notes that GIB-Cove profiles are available in 3.6 m lengths. For a 15 m wall, the calculator indicates you need 5 lengths of 3.6 m cornice. Note these regional differences when ordering your trim. If you are lining a ceiling as well, ensure you have enough material to cover the perimeter of the entire room.
Worked example
To understand how the calculator arrives at these figures, we can look at the scenario for a room with 15 m of wall, a 2.4 m height, and a 14 m2 ceiling.
First, we calculate the total area to line. The wall area is 15 m multiplied by 2.4 m, which equals 36 m2. Adding the 14 m2 ceiling brings the total area to 50 m2.
Next, we determine the area of a single sheet of plasterboard. Using a standard 1200 mm by 2400 mm sheet, the area is 2.88 m2.
Then, we divide the total area by the area of one sheet: 50 m2 divided by 2.88 m2 equals 19.1 sheets.
Finally, we apply the 10% waste factor and round up to the nearest whole sheet, resulting in a purchase of 20 sheets. For the screws, 50 m2 multiplied by 8 screws per m2 with 10% waste (50 × 1.1 × 8) equals 440 screws. The jointing compound for this area is 13 kg, which fits into 1 pack of 20 kg.
| Item | AU Requirement | NZ Requirement |
|---|---|---|
| Plasterboard 10 mm (1200 x 2400 mm) | 14 sheets (36.0 m2) | 14 sheets (36.0 m2) |
| Plasterboard screws | 317 screws | 317 screws |
| Jointing compound (20 kg packs) | 1 pack | 1 pack |
| Cornice | 15 m | 5 lengths (3.6 m) |
| Plasterboard 10 mm (1200 x 2400 mm) with 14 m2 ceiling | 20 sheets (50.0 m2) | 20 sheets (50.0 m2) |
| Plasterboard screws (with ceiling) | 441 screws | 441 screws |
| Jointing compound (with ceiling) | 1 pack | 1 pack |
| Cornice (with ceiling) | 15 m | 5 lengths (3.6 m) |
Common mistakes
One common mistake is failing to account for waste. Always include a 10% buffer for offcuts, as the calculator uses this as a standard rule of thumb. Another error is neglecting the difference in sheet sizes; a 1200 x 2400 mm sheet covers significantly less area than a 1200 x 3000 mm sheet. Homeowners also sometimes forget to calculate the ceiling area separately from the walls. Finally, check regional differences, such as the cornice lengths in New Zealand versus Australia, to avoid ordering the wrong quantity of trim.
Frequently asked questions
What is the standard width for plasterboard?
The Gyprock Standard 13 mm product page lists widths of 900, 1200, 1350, and 1400 mm, with 1200 mm being a common width.
How many screws are needed per square metre?
The GIB site guide suggests a coverage of approximately 800 screws per 100 m2, which is 8 screws per m2.
What is the maximum spacing for fasteners?
The Gyprock FAQ and the GIB general wall and ceiling installation guide both state a maximum of 300 mm centres for fasteners.
How much jointing compound is needed for topping?
Gyprock Jointmaster topping covers 10 kg per 100 m2.
Are there different sheet lengths available?
Yes, Gyprock lists lengths including 2400, 2700, 3000, 3600, 4200, 4800, and 6000 mm, though stocked sizes vary by region.
Sources and assumptions
These are the settings behind every number above. Verified figures link to a source. Editable defaults are common rules of thumb: change them to match your product and your site.